Set-up guide

Contents

What's in the box

Inspection certificate

Ceramic reference tile

USB-C Charging Cable

Set-up steps

Step 1

Wake up your device

Wake up your by plugging it into the USB-C cable, and the cable into a charger. The lid of the device will indicate it’s connected to power. As it’s charging, it will slowly pulse orange 4 times, then stay dimly lit. Once charging is complete it will slowly pulse green 4 times, then stay dimly lit. Make sure to allow your device to fully charge before unplugging (about four hours).

Step 2

Download the app

Step 3

Enable location + wireless connectivity permissions

You must allow location services and wireless connectivity on your device for your to function.

Step 4

Connect your device

Step 5

Start scanning and measuring colors

Tips + tricks

Maintaining your device:

  • Charge your device every month when not in use.
  • Keep the lens clean of all dirt, lint, and smudges. Always store your device in the included industrial carrying case.
    • Dust and debris can be removed by gently wiping the lens with a dry microfiber cloth. Do not use a cleaning solution on your device.
  • If your reference tile requires cleaning, wipe it with a dry microfiber cloth (provided). Never use any cleaning solution on the tile. Use only the provided cloth, as other materials may be dyed and can stain the reference tile.
  • Avoid dropping or hitting your device.
  • Don’t use outside of 5 – 35°C temperature range. If you bring your device in from outside, allow it to come to temperature slowly to avoid condensation.
  • Surfaces that aren’t flat or solid can be difficult to measure accurately. To avoid poor scanning conditions, pair your device with one of Nix Sensor’s carefully crafted adapters. Instructions for using the adapters can be found below:

Objects with textures, patterns, extreme gloss, or soft surfaces may be less accurate.

The works best on solid opaque surfaces.

Ensure your device is placed flat to the scanned surface before scanning.

Using the reference tile

Nix Sensor Ltd. has designed a durable platform built upon an all-metal chassis, sealed tempered glass lenses, and no moving parts. Our devices use solid-state light sources (LEDs) and automatically compensate for small ambient temperature changes. These light sources are rated for hundreds of thousands of measurements over their lifetime. Under normal operating conditions, the does not need daily calibration.

You may want to either check your calibration status or perform a calibration if:

  • Significant ambient temperature changes (greater than 10°C) have been experienced since the last calibration.
  • More than one week has elapsed since the last calibration.
  • You have taken over 1000 measurements since your last calibration.
  • You suspect you may have physically shocked your device.
  • You are experiencing unreliable results.

Note: For proper operation, you must ensure that your device’s lens is clean and your calibration tile is well maintained. Please see the “Tips + Tricks” section for information on proper maintenance.

1

Open the reference tile that was shipped with your .

2

From the Nix Toolkit app, open up device info and select “Perform white tile normalization”.

3

Walk through the steps on your app, and scan the QR code on the reference tile (make sure you enable permissions for the app to use your camera).

4

Remove any adapters or jigs from your device. Place your on the designated white patch of the tile. Press “Scan” in the Nix Toolkit app to run calibration.

If your device is failing calibration, .

RGB lid indicator

The lid of your has an RGB light that indicates certain activity related to your device. For any RGB feedback not mentioned in the tables below, please  and we’ll be happy to help you resolve your issue.

Plugged into power source, not connected to software

Color

Feedback

Description

Orange

4 slow pulses, then stays dimly lit

Actively charging.

Green

4 slow pulses, then stays dimly lit

Charging complete.

Red

Flashing

Charging error. Please .

Connected to software

Color

Feedback

Description

White

2 quick pulses

USB connection opened/closed.

Cyan

2 quick pulses

Wireless connection opened/closed.

Blue

Stale

Measurement in progress.

Green

2 quick pulses, fades after 5 seconds

Measurement ended successfully.

Red

3 quick pulses, fades after 5 seconds

Measurement ended unsuccessfully. Refer to the error message shown in the software for further instructions. If you keep experiencing this error, please .

FAQs

Device

How do I reset my device?

The automatically resets when it is connected to a USB charger. Additionally, there is a small hole at the bottom of the device. Gently use a paperclip through the hole to access a reset button.

My device seems stuck

If you’re having trouble with your device, try these steps:

  1. Force quit and restart your app.
  2. Recharge your device until the lid is pulsing green (indicating charging is complete).
  3. If you’re still experiencing issues, .

I've tried everything and my won't connect. What do I do?

  1. Make sure your device is close to your phone before pairing.
  2. Follow the set-up steps above.
  3. If you’re still having trouble, .

Charging time and procedure

Charging your should take approximately 4 hours from a standard USB charger. When charging starts the lid should slowly pulse orange 4 times, then stay dimly lit. When charging has completed it will slowly pulse green 4 times, then stay dimly lit.

Reference tile

What's the reference tile for?

The reference tile allows for periodic in-field calibration of your device for improved performance and accuracy.

How often should I use my reference tile?

You may want to perform a calibration with the reference tile if:

  • Significant ambient temperature changes (greater than 10°C) have been experienced since the last calibration.
  • More than one week has elapsed since the last calibration.
  • You have taken over 1000 measurements since the last calibration.
  • You suspect you may have physically shocked your device.
  • You are experiencing unreliable results.

How do I care for my reference tile?

  • Keep the protective case closed when the tile is not in use.
  • Keep your tile in a clean, dry, secure place.
  • If your reference tile requires cleaning, wipe it with a dry microfiber cloth (provided). Never use any cleaning solution on the tile. Use only the provided cloth, as other materials may be dyed and can stain the reference tile.

How do I replace a lost or damaged reference tile?

Your reference tile has been paired with your specific device during its manufacture. To inquire about replacements, .